    超聲波換能器的容易出現的問題匯總

    作者:admin來源:http://www.bolomie.com/時間:2021-03-13

    91视频破解版由超聲波發生器和超聲波換能器組成,超聲波換能器是由壓電陶瓷材料製造的夾芯式換能器,壓電陶瓷材料在交變電場的作用下會產生機械振動。

    Ultrasonic cleaning machine is composed of ultrasonic generator and ultrasonic transducer. Ultrasonic transducer is a sandwich transducer made of piezoelectric ceramic materials. Piezoelectric ceramic materials will produce mechanical vibration under the action of alternating electric field.

    超聲波換能器是91视频破解版的重要組成部分,91视频破解版出現問題的時候很可能就是超聲波換能器出現問題,本文就將帶大家了解下91视频破解版換能器常見的四大問題:

    The ultrasonic transducer is an important part of the ultrasonic cleaning machine. When the ultrasonic cleaning machine has problems, it is likely that the ultrasonic transducer has problems. This paper will take you to understand the four common problems of the ultrasonic cleaning machine transducer

    2-210313164951A6.jpg

    1.超聲波換能器受潮。一般用兆歐表檢查和換能器相連接的插頭,檢查換能器正負極間的絕緣電阻值就可以判斷。一般要求絕緣電阻大於30兆歐以上。如果達不到這個絕緣電阻值,很可能是換能器受潮。

    1. The ultrasonic transducer is damp. Generally, the plug connected to the transducer is checked with a megohmmeter, and the insulation resistance value between the positive and negative poles of the transducer can be judged. Generally, the insulation resistance is more than 30 megohm. If the insulation resistance value is not reached, it is likely that the transducer is affected by moisture.

    維修方法是把換能器整體(不包括噴塑外殼)放進烘箱設定100℃左右,烘幹三小時或者使用電吹風去潮至阻值正常為止。換能器振子打火,陶瓷材料碎裂。維修時可以用肉眼和兆歐表結合檢查。一般作為應急處理的措施,可以把個別損壞的換能器斷開,不會影響到別的換能器正常使用。

    The maintenance method is to put the whole transducer (excluding the plastic spraying shell) into the oven, set it at about 100 ℃, dry it for three hours or use an electric hair dryer to remove moisture until the resistance is normal. The transducer vibrator ignited and the ceramic material was broken. During maintenance, it can be checked with naked eye and megohmmeter. Generally, as an emergency measure, individual damaged transducers can be disconnected, which will not affect the normal use of other transducers.

    2.換能器脫膠。91视频下载安装知道大多數廠家采用膠粘的方式固定換能器,但91视频破解版的長期使用後由於振動會出現脫膠現象。也有廠家采用膠結加螺釘緊固的方式,一般情況下不會出現脫膠,由於螺釘的作用,振子脫膠後不會從振動麵上落下,一般的判斷方法是用手輕搖振子的尾部,仔細觀察振動麵的膠水情況做出判斷。

    2. Transducer degumming. We know that most manufacturers use adhesive way to fix the transducer, but after long-term use of ultrasonic cleaning machine, it will appear degumming phenomenon due to vibration. Some manufacturers also adopt the way of cementation and screw fastening, which generally will not occur degumming. Due to the role of the screw, the vibrator will not fall from the vibration surface after degumming. The general judgment method is to gently shake the tail of the vibrator by hand, carefully observe the glue situation of the vibration surface, and make a judgment.

    3.一般振子出現脫膠以後超聲波

    3. After the general vibrator appears degumming, ultrasonic

    電源輸出的功率正常,但是由於振子與振動麵連接不好,振動麵的振動效果不好,長時間後由於能量無法釋放出去,很可能會燒壞振子。振子脫膠對於用戶來說維修起來是比較麻煩的,一般情況隻能送回生產廠家進行維修處理。避免振子脫膠有用的方法是平時使用中注意不撞擊振動麵。

    The power output of the power supply is normal, but the vibration effect of the vibration surface is not good due to the poor connection between the vibrator and the vibration surface. After a long time, because the energy can not be released, the vibrator is likely to be burnt out. Vibration degumming is troublesome for the user to maintain. Generally, it can only be sent back to the manufacturer for maintenance. A useful way to avoid the degumming of the vibrator is not to hit the vibrating surface in normal use.

    4.振動麵穿孔。一般超聲波換能器滿負荷使用數年以後可能會出現振動麵穿孔的情況,這是由於振動麵的不鏽鋼板長時間高頻振動疲勞所致,振動麵穿孔說明換能器的使用壽命已經到了,91视频破解版在維修上一般隻能更換。

    4. The vibration surface is perforated. In general, after the ultrasonic transducer is used at full load for several years, the vibration surface may be perforated, which is caused by the high frequency vibration fatigue of the stainless steel plate of the vibration surface for a long time. The perforation of the vibration surface indicates that the service life of the transducer has come, and the ultrasonic cleaning machine can only be replaced in the maintenance.